BTXMS - LONCOTERGE 200, LT 220
- MSDS: BTXMS
- Manufacturer: UNION CARBIDE
- Product Name: LONCOTERGE 200, LT 220
- National Stock Number: 8030-00N045930
Product Identification
Product ID:LONCOTERGE 200, LT 220
MSDS Date:08/22/1989
FSC:8030
NIIN:00N045930
MSDS Number: BTXMS
Responsible Party
DANBURY, CT 06817
US
Emergency Phone: 304-744-3487
Info Phone: 304-744-3487
Cage: 07098
Contractor
Telephone: 800-822-4357
Cage: 07098
Ingredients
SODIUM HYDROXIDE (SARA III)
CAS: 1310-73-2
RTECS: WB4900000
Fraction By Weight: 70-80%
OSHA PEL 2 MG/M3, C
ACGIH TLV: 2 MG/M3, C
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
POTASSIUM HYDROXIDE (SARA III)
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 2-6%
OSHA PEL 2 MG/M3, C
ACGIH TLV: 2 MG/M3, C
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INGEST: MODERATELY TOX. MAY
CAUSE BURNS OF THE MOUTH & DIGESTIVE TRACT, NAUS, VOMITING,
ABDOMINAL PAIN, & DIARRHEA. SKIN CONTACT: CAUSES IRRIT, WITH
REDDENING & ITCHING. PRLNGD CNTCT, AS FROM CL THG WETTED W/THE
MATL, MAY CAUSE CHEM BURNS. INHAL: VAPORS/MISTS MAY CAUSE RESP
IRRIT. EYE: LIQ CAUSES (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS: SEVERE IRRIT, CONJUNCTIVITIS, AND
POSSIBLE CHEMICAL BURNS. VAPORS MAY CAUSE IRRITATION AND EXCESS
PRODUCTION OF TEARS.
Medical Cond Aggravated by Exposure:DUE TO ITS IRRITATING PROPERTIES,
THIS MATERIAL MAY AGGRAVATE AN EXISTING DERMATITIS.
First Aid
First Aid:INGEST: GIVE TWO GLASSES OF WATER. DO NOT INDUCE VOMIT. CALL
MD. SKIN: REMOVE CONTAM CLTHG & WASH SKIN THORO WITH SOAP & WATER.
SEEK MED ATTN IF IRRIT OCCURS. INHAL: REMOVE TO FRESH AIR. EYES:
IMMED F LUSH EYES THORO W/WATER & CONTINUE FOR @ LST 15 MIN. SEEK
MED ATTN URGENTLY, PREFERABLY AN OPHTHALMOLOGIST. NOTE TO MD:THERE
IS NO SPECIFIC ANTIDOTE. TREATMENT OF OVEREXP SHOULD BE
DIRECTED(SUPP DATA)
Fire Fighting
Flash Point:NONE
Extinguishing Media:NORMALLY NOT FLAMMABLE; USE EXTINGUISHING MEDIUM
APPROPRIATE TO SURROUNDING FIRE.
Fire Fighting Procedures:USE BLANKET EFFECT TO SMOTHER FIRE, USE WATER
ONLY IN FINE MIST OR SPRAY. FIREFIGHTERS SHOULD WEAR NIOSH/MSHA
APPROVED SCBA AND FULL PROT EQUIP .
Unusual Fire/Explosion Hazard:NONE KNOWN.
Accidental Release
Spill Release Procedures:CONTAIN SPILL. COLLECT IN CONTAINERS FOR
DISPOSAL. CAUTION: MATERIAL IS SLIPPERY TO WALK ON.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN CLOSED CONTAINERS IN A
WELL-VENT LOW FIRE-RISK AREA AWAY FROM ACIDS, AND OXIDIZING AGENTS
AND AWAY FROM SOURCES OF HEAT AND IGNITION.
Other Precautions:AVOID UNPROTECTED SKIN AND EYE CONTACT. USE WITH GOOD
VENTILATION.
Exposure Controls
Respiratory Protection:NOT NORMALLY NEEDED. IF REDUCED TO DRYNESS, USE
NIOSH/MSHA APPROVED PARTICULATE RESPIRATORS WHERE DUST EXPOSURES
EXCEED PEL.
Ventilation:USE LOCAL OR GENERAL DILUTION VENTILATION TO MAINTAIN
EXPOSURE BELOW THE EXPOSURE LIMITS.
Protective Gloves:NITRILE OR SUPPORTED NEOPRENE.
Eye Protection:ANSI APPVD CHEM WORK GOGG W/FULL (SUPDAT
Other Protective Equipment:USE NEOPRENE APRON WHERE POTENTIAL FOR
SPLASHING EXISTS. ANSI APPVD EYE WASH IS RECOMMENDED .
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
FIRST AID PROC: AT THE CONTROL OF SYMPTOMS AND CLINICAL CONDITION. EYE
PROT: LGTH FCSHLD .
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:AS WATER
Vapor Density:AS WATER
Spec Gravity:1.15 (H2O=1)
Evaporation Rate & Reference:> 1 (BUTYL ACETATE=1)
Solubility in Water:100%
Appearance and Odor:LIGHT AMBER LIQUID WITH ODOR OF SOAP
Percent Volatiles by Volume:70
Stability
Stability Indicator/Materials to Avoid:YES
WILL REACT WITH ACID LIBERATING HEAT.
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:SMALL AMOUNTS OF CARBON DIOXIDE IN
FIRE CONDITIONS.
Disposal
Waste Disposal Methods:SCRAP LIQUID MAY BE PROCESSED (AT 10PPM) THROUGH
A WASTE-WATER TREATMENT FACILITY WITH NEUTRALIZATION CAPABILITY OR
DISPOSED VIA A LICENSED WASTE DISPOSAL SERVICE. DISP MUST BE IN
ACCORDANCE WITH FEDE RAL, STATE AND LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.